multiphysics heat transfer model Search Results


90
COMSOL Inc three-dimensional steady-state heat transfer model comsol multiphysics
Three Dimensional Steady State Heat Transfer Model Comsol Multiphysics, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/three-dimensional steady-state heat transfer model comsol multiphysics/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
three-dimensional steady-state heat transfer model comsol multiphysics - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc multiphysics heat transfer model
Multiphysics Heat Transfer Model, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/multiphysics heat transfer model/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
multiphysics heat transfer model - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc finite element heat transfer model comsol multiphysics v 4.2
Finite Element Heat Transfer Model Comsol Multiphysics V 4.2, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/finite element heat transfer model comsol multiphysics v 4.2/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
finite element heat transfer model comsol multiphysics v 4.2 - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc pennes bioheat equation in a comsol multiphysics heat transfer model
Pennes Bioheat Equation In A Comsol Multiphysics Heat Transfer Model, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pennes bioheat equation in a comsol multiphysics heat transfer model/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
pennes bioheat equation in a comsol multiphysics heat transfer model - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc pennes bio-heat transfer model in comsol multiphysics
Pennes Bio Heat Transfer Model In Comsol Multiphysics, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pennes bio-heat transfer model in comsol multiphysics/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
pennes bio-heat transfer model in comsol multiphysics - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc simulation model comsol multiphysics conjugate heat transfer module
Simulation Model Comsol Multiphysics Conjugate Heat Transfer Module, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/simulation model comsol multiphysics conjugate heat transfer module/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
simulation model comsol multiphysics conjugate heat transfer module - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc three-dimensional heat transfer model using comsol multiphysics 4.2a software
Three Dimensional Heat Transfer Model Using Comsol Multiphysics 4.2a Software, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/three-dimensional heat transfer model using comsol multiphysics 4.2a software/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
three-dimensional heat transfer model using comsol multiphysics 4.2a software - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc 3d heat transfer model comsol multiphysics v5.6
(a) Thermal images of ITO-10 NP samples printed with different parameters, exposed to IR lamp irradiation (100 W@50 cm), acquired ad different times, as in panel (b); sample 25DS 1 L, 25DS 2 L, 25DS 2 L, and 25DS 2 L refer to various combinations of drop spacing (DS = 25, 50 μm) and number of printed layers (L = 1, 2). (b) Thermal dynamics of the same samples, averaged with an ROI (region of interest) of 0.5 × 0.5cm 2 placed in the center of the printed squares. Irradiation with the IR lamp starts at 0 s and ends at 36 s. (c) Evaluation of thermal pattern resolution considering the two different designs “interline” and “linewidth”, performed on a specific printed sample exposed to the IR lamp (100 W@50 cm): interline on the left has widths of 2500, 1000, 500, and 250 μm (from top to bottom); linewidth on the right has widths of 2500, 1000, 500, and 250 μm (from top to bottom). (d) Simulated thermal image of the 25DS 1 L square sample (1 cm side) obtained by finite element modeling (FEM) <t>Multiphysics</t> software. (e) Thermal resolution, evaluated as the gradient of temperature along the x axis at the edge of the ITO square vs substrate thickness and time, obtained by simulation. Timestamp in panels (a), (c), and (d) indicates the time elapsed from IR irradiation starting.
3d Heat Transfer Model Comsol Multiphysics V5.6, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/3d heat transfer model comsol multiphysics v5.6/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
3d heat transfer model comsol multiphysics v5.6 - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc 3d integrated heat transfer model with the stick-slip condition using comsol multiphysics
(a) Thermal images of ITO-10 NP samples printed with different parameters, exposed to IR lamp irradiation (100 W@50 cm), acquired ad different times, as in panel (b); sample 25DS 1 L, 25DS 2 L, 25DS 2 L, and 25DS 2 L refer to various combinations of drop spacing (DS = 25, 50 μm) and number of printed layers (L = 1, 2). (b) Thermal dynamics of the same samples, averaged with an ROI (region of interest) of 0.5 × 0.5cm 2 placed in the center of the printed squares. Irradiation with the IR lamp starts at 0 s and ends at 36 s. (c) Evaluation of thermal pattern resolution considering the two different designs “interline” and “linewidth”, performed on a specific printed sample exposed to the IR lamp (100 W@50 cm): interline on the left has widths of 2500, 1000, 500, and 250 μm (from top to bottom); linewidth on the right has widths of 2500, 1000, 500, and 250 μm (from top to bottom). (d) Simulated thermal image of the 25DS 1 L square sample (1 cm side) obtained by finite element modeling (FEM) <t>Multiphysics</t> software. (e) Thermal resolution, evaluated as the gradient of temperature along the x axis at the edge of the ITO square vs substrate thickness and time, obtained by simulation. Timestamp in panels (a), (c), and (d) indicates the time elapsed from IR irradiation starting.
3d Integrated Heat Transfer Model With The Stick Slip Condition Using Comsol Multiphysics, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/3d integrated heat transfer model with the stick-slip condition using comsol multiphysics/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
3d integrated heat transfer model with the stick-slip condition using comsol multiphysics - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc multiphysics 5.5 heat transfer model
(a) Thermal images of ITO-10 NP samples printed with different parameters, exposed to IR lamp irradiation (100 W@50 cm), acquired ad different times, as in panel (b); sample 25DS 1 L, 25DS 2 L, 25DS 2 L, and 25DS 2 L refer to various combinations of drop spacing (DS = 25, 50 μm) and number of printed layers (L = 1, 2). (b) Thermal dynamics of the same samples, averaged with an ROI (region of interest) of 0.5 × 0.5cm 2 placed in the center of the printed squares. Irradiation with the IR lamp starts at 0 s and ends at 36 s. (c) Evaluation of thermal pattern resolution considering the two different designs “interline” and “linewidth”, performed on a specific printed sample exposed to the IR lamp (100 W@50 cm): interline on the left has widths of 2500, 1000, 500, and 250 μm (from top to bottom); linewidth on the right has widths of 2500, 1000, 500, and 250 μm (from top to bottom). (d) Simulated thermal image of the 25DS 1 L square sample (1 cm side) obtained by finite element modeling (FEM) <t>Multiphysics</t> software. (e) Thermal resolution, evaluated as the gradient of temperature along the x axis at the edge of the ITO square vs substrate thickness and time, obtained by simulation. Timestamp in panels (a), (c), and (d) indicates the time elapsed from IR irradiation starting.
Multiphysics 5.5 Heat Transfer Model, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/multiphysics 5.5 heat transfer model/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
multiphysics 5.5 heat transfer model - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc coupled electromagnetic and heat transfer model comsol multiphysics
(a) Thermal images of ITO-10 NP samples printed with different parameters, exposed to IR lamp irradiation (100 W@50 cm), acquired ad different times, as in panel (b); sample 25DS 1 L, 25DS 2 L, 25DS 2 L, and 25DS 2 L refer to various combinations of drop spacing (DS = 25, 50 μm) and number of printed layers (L = 1, 2). (b) Thermal dynamics of the same samples, averaged with an ROI (region of interest) of 0.5 × 0.5cm 2 placed in the center of the printed squares. Irradiation with the IR lamp starts at 0 s and ends at 36 s. (c) Evaluation of thermal pattern resolution considering the two different designs “interline” and “linewidth”, performed on a specific printed sample exposed to the IR lamp (100 W@50 cm): interline on the left has widths of 2500, 1000, 500, and 250 μm (from top to bottom); linewidth on the right has widths of 2500, 1000, 500, and 250 μm (from top to bottom). (d) Simulated thermal image of the 25DS 1 L square sample (1 cm side) obtained by finite element modeling (FEM) <t>Multiphysics</t> software. (e) Thermal resolution, evaluated as the gradient of temperature along the x axis at the edge of the ITO square vs substrate thickness and time, obtained by simulation. Timestamp in panels (a), (c), and (d) indicates the time elapsed from IR irradiation starting.
Coupled Electromagnetic And Heat Transfer Model Comsol Multiphysics, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/coupled electromagnetic and heat transfer model comsol multiphysics/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
coupled electromagnetic and heat transfer model comsol multiphysics - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc multiphysics conductive and radiative heat transfer model
(a) Thermal images of ITO-10 NP samples printed with different parameters, exposed to IR lamp irradiation (100 W@50 cm), acquired ad different times, as in panel (b); sample 25DS 1 L, 25DS 2 L, 25DS 2 L, and 25DS 2 L refer to various combinations of drop spacing (DS = 25, 50 μm) and number of printed layers (L = 1, 2). (b) Thermal dynamics of the same samples, averaged with an ROI (region of interest) of 0.5 × 0.5cm 2 placed in the center of the printed squares. Irradiation with the IR lamp starts at 0 s and ends at 36 s. (c) Evaluation of thermal pattern resolution considering the two different designs “interline” and “linewidth”, performed on a specific printed sample exposed to the IR lamp (100 W@50 cm): interline on the left has widths of 2500, 1000, 500, and 250 μm (from top to bottom); linewidth on the right has widths of 2500, 1000, 500, and 250 μm (from top to bottom). (d) Simulated thermal image of the 25DS 1 L square sample (1 cm side) obtained by finite element modeling (FEM) <t>Multiphysics</t> software. (e) Thermal resolution, evaluated as the gradient of temperature along the x axis at the edge of the ITO square vs substrate thickness and time, obtained by simulation. Timestamp in panels (a), (c), and (d) indicates the time elapsed from IR irradiation starting.
Multiphysics Conductive And Radiative Heat Transfer Model, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/multiphysics conductive and radiative heat transfer model/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
multiphysics conductive and radiative heat transfer model - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

Image Search Results


(a) Thermal images of ITO-10 NP samples printed with different parameters, exposed to IR lamp irradiation (100 W@50 cm), acquired ad different times, as in panel (b); sample 25DS 1 L, 25DS 2 L, 25DS 2 L, and 25DS 2 L refer to various combinations of drop spacing (DS = 25, 50 μm) and number of printed layers (L = 1, 2). (b) Thermal dynamics of the same samples, averaged with an ROI (region of interest) of 0.5 × 0.5cm 2 placed in the center of the printed squares. Irradiation with the IR lamp starts at 0 s and ends at 36 s. (c) Evaluation of thermal pattern resolution considering the two different designs “interline” and “linewidth”, performed on a specific printed sample exposed to the IR lamp (100 W@50 cm): interline on the left has widths of 2500, 1000, 500, and 250 μm (from top to bottom); linewidth on the right has widths of 2500, 1000, 500, and 250 μm (from top to bottom). (d) Simulated thermal image of the 25DS 1 L square sample (1 cm side) obtained by finite element modeling (FEM) Multiphysics software. (e) Thermal resolution, evaluated as the gradient of temperature along the x axis at the edge of the ITO square vs substrate thickness and time, obtained by simulation. Timestamp in panels (a), (c), and (d) indicates the time elapsed from IR irradiation starting.

Journal: ACS Applied Materials & Interfaces

Article Title: Invisible Thermoplasmonic Indium Tin Oxide Nanoparticle Ink for Anti-counterfeiting Applications

doi: 10.1021/acsami.2c10864

Figure Lengend Snippet: (a) Thermal images of ITO-10 NP samples printed with different parameters, exposed to IR lamp irradiation (100 W@50 cm), acquired ad different times, as in panel (b); sample 25DS 1 L, 25DS 2 L, 25DS 2 L, and 25DS 2 L refer to various combinations of drop spacing (DS = 25, 50 μm) and number of printed layers (L = 1, 2). (b) Thermal dynamics of the same samples, averaged with an ROI (region of interest) of 0.5 × 0.5cm 2 placed in the center of the printed squares. Irradiation with the IR lamp starts at 0 s and ends at 36 s. (c) Evaluation of thermal pattern resolution considering the two different designs “interline” and “linewidth”, performed on a specific printed sample exposed to the IR lamp (100 W@50 cm): interline on the left has widths of 2500, 1000, 500, and 250 μm (from top to bottom); linewidth on the right has widths of 2500, 1000, 500, and 250 μm (from top to bottom). (d) Simulated thermal image of the 25DS 1 L square sample (1 cm side) obtained by finite element modeling (FEM) Multiphysics software. (e) Thermal resolution, evaluated as the gradient of temperature along the x axis at the edge of the ITO square vs substrate thickness and time, obtained by simulation. Timestamp in panels (a), (c), and (d) indicates the time elapsed from IR irradiation starting.

Article Snippet: We implemented a 3D heat transfer model in COMSOL Multiphysics v5.6 in order to investigate the achievable thermal resolution as a function of substrate thickness and exposure time.

Techniques: Irradiation, Software